{"product_id":"cem-epix-fc-360-epoxy-floor-basecoat","title":"CEM EPIX FC-360 High-Solids Epoxy Basecoat – 3-Gallon Kit","description":"\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCEM EPIX FC-360 High-Solids Epoxy Basecoat\u003c\/span\u003e\u003cspan\u003e is a two-component epoxy for properly prepared concrete floors beneath decorative flake, metallic, and solid-color flooring systems. Suitable projects include garages, showrooms, warehouses, and retail floors. Part A comes in a \u003c\/span\u003e\u003cspan\u003e2-gallon container\u003c\/span\u003e\u003cspan\u003e and Part B in a \u003c\/span\u003e\u003cspan\u003e1-gallon container\u003c\/span\u003e\u003cspan\u003e. Mix \u003c\/span\u003e\u003cspan\u003e2 parts A to 1 part B by volume\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eSuitable Applications \u0026amp; Restrictions\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eUse CEM EPIX FC-360 as a basecoat on properly prepared concrete floors.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv dir=\"ltr\" align=\"left\"\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"151\"\u003e\n\u003ccol width=\"463\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eProject examples\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eGarages, warehouses, showrooms, retail floors, aircraft hangars, and auto service centers.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eSurface preparation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eConcrete must be clean, dry, and free of contaminants. Follow the manufacturer’s preparation instructions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMoisture restrictions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNot recommended for surfaces with excessive moisture. Obtain CEM Coating Systems’ required moisture tests and acceptance limits, and confirm that the concrete meets them before application.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eExisting coatings and other substrates\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eConfirm compatibility and required preparation with CEM Coating Systems before use.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eColor Options\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eChoose your basecoat color from the available options.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eSwatches are approximate. Flakes, metallic pigments, and the topcoat can affect how the finished floor looks. Review a finished sample of your chosen flooring system before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eKey Features \u0026amp; Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\n\u003cspan\u003eConcrete adhesion:\u003c\/span\u003e\u003cspan\u003e Bonds to properly prepared concrete floors.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\n\u003cspan\u003eHigh-solids formula:\u003c\/span\u003e\u003cspan\u003e Two-component, cycloaliphatic amine epoxy.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\n\u003cspan\u003eDecorative flooring basecoat:\u003c\/span\u003e\u003cspan\u003e Forms the base layer beneath compatible decorative floor coatings.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\n\u003cspan\u003eFast curing:\u003c\/span\u003e\u003cspan\u003e Listed tack-free time is \u003c\/span\u003e\u003cspan\u003e3–4 hours\u003c\/span\u003e\u003cspan\u003e. Follow the separate recoating and traffic requirements\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eProduct Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv dir=\"ltr\" align=\"left\"\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"188\"\u003e\n\u003ccol width=\"313\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eProduct\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCEM EPIX FC-360\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eTwo-component epoxy floor basecoat\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFormulation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eHigh-solids, cycloaliphatic amine epoxy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003ePackage Contents\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e3-gallon kit: 2 gallons Part A + 1 gallon Part B\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMix Ratio\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e2 parts A to 1 part B by volume\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFinish\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eHigh gloss\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMixed VOC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eLess than 100 g\/L\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eApplication Temperature\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e50°F–80°F\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003ePot Life\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e20 minutes at 77°F\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eIntended Use\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eProfessional use only\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eCoverage\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe technical sheet lists \u003c\/span\u003e\u003cspan\u003e125–175 square feet per gallon\u003c\/span\u003e\u003cspan\u003e. Actual coverage varies with concrete porosity, surface texture, application method, and existing coatings.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv dir=\"ltr\" align=\"left\"\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"332\"\u003e\n\u003ccol width=\"158\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eListed Coverage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFirst coat on concrete\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e125–175 ft² per gallon\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eSecond coat over a compatible existing coating\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e125–175 ft² per gallon\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eBefore calculating your order, confirm with CEM Coating Systems whether this rate applies to mixed Part A and Part B, the required film thickness, and the number of coats. Coverage for other components in the flooring system must be calculated separately.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eSurface Preparation \u0026amp; Application Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003col\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\n\u003cspan\u003eAssess the concrete.\u003c\/span\u003e\u003cspan\u003e Check its condition and moisture suitability using the manufacturer’s required tests and acceptance limits.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\n\u003cspan\u003ePrepare the surface. \u003c\/span\u003e\u003cspan\u003eFollow CEM Coating Systems’ required preparation method and concrete surface profile. Leave the surface clean, dry, and free of contaminants. \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\n\u003cspan\u003eMix each component separately.\u003c\/span\u003e\u003cspan\u003e Mix Part A and Part B individually before combining them.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\n\u003cspan\u003eCombine and mix.\u003c\/span\u003e\u003cspan\u003e Use \u003c\/span\u003e\u003cspan\u003e2 parts A to 1 part B by volume\u003c\/span\u003e\u003cspan\u003e. Mix for \u003c\/span\u003e\u003cspan\u003e2–3 minutes\u003c\/span\u003e\u003cspan\u003e with a low-speed drill mixer at \u003c\/span\u003e\u003cspan\u003e300–450 rpm\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\n\u003cspan\u003eApply immediately.\u003c\/span\u003e\u003cspan\u003e Pour the mixed epoxy onto the concrete and spread evenly with a flat squeegee or roller. Avoid excessive buildup. Pot life is \u003c\/span\u003e\u003cspan\u003e20 minutes at 77°F\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\n\u003cspan\u003eFollow your decorative system’s instructions.\u003c\/span\u003e\u003cspan\u003e For a full-broadcast flake system, broadcast flakes into the wet basecoat to full rejection. Use the specified application sequence for metallic or solid-color systems.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\n\u003cspan\u003eApply the next coat.\u003c\/span\u003e\u003cspan\u003e Use a manufacturer-approved coating within its specified application window. If the window is missed, obtain the required surface-preparation instructions before proceeding.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eApply within \u003c\/span\u003e\u003cspan\u003e50°F–80°F\u003c\/span\u003e\u003cspan\u003e. Read the current technical sheet and safety data sheets for both components before use.\u003c\/span\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eWorking, Recoating \u0026amp; Traffic Times\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv dir=\"ltr\" align=\"left\"\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"119\"\u003e\n\u003ccol width=\"97\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eStage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eListed Time\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003ePot life at 77°F\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e20 minutes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eTack-free\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e3–4 hours\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eRecoat window\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e2–9 hours\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFoot traffic\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e12–16 hours\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eHeavy traffic\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e2–7 days\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eOnly pot life has a stated temperature of \u003c\/span\u003e\u003cspan\u003e77°F\u003c\/span\u003e\u003cspan\u003e. Confirm the conditions for the remaining times before planning application or reopening the floor. Tack-free does not mean fully cured or ready for traffic.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFollow the traffic requirements for the complete coating system, including its topcoat. The listed heavy-traffic time does not establish vehicle-traffic readiness or full cure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eIf the recoat window is missed:\u003c\/span\u003e\u003cspan\u003e Obtain CEM Coating Systems’ surface-preparation instructions before applying another coat. Also check the application window for your selected topcoat.\u003c\/span\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eSafety \u0026amp; Product Documents\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFor professional use only.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\n\u003cspan\u003eVentilation:\u003c\/span\u003e\u003cspan\u003e Use only in well-ventilated areas.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\n\u003cspan\u003eProtective equipment:\u003c\/span\u003e\u003cspan\u003e Wear suitable gloves and goggles. Avoid contact with skin and eyes. Follow each component’s SDS for additional protective equipment.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\n\u003cspan\u003eStorage:\u003c\/span\u003e\u003cspan\u003e Store above \u003c\/span\u003e\u003cspan\u003e40°F\u003c\/span\u003e\u003cspan\u003e and keep out of children’s reach.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: -webkit-left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0845\/4537\/2388\/files\/cem-epix-fc-360-technical-data-sheet.jpg?v=1792592916\" alt=\"CEM EPIX FC-360 technical data sheet with mixing ratio, coverage, application instructions, and curing times\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eCan I mix a smaller batch?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eConfirm with CEM Coating Systems that partial-batch mixing is permitted. The specified ratio is \u003c\/span\u003e\u003cspan\u003e2 parts A to 1 part B by volume\u003c\/span\u003e\u003cspan\u003e. Follow the manufacturer’s measuring and mixing instructions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eCan FC-360 be used without a topcoat?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFC-360 is described as a basecoat for decorative flooring systems. The technical sheet does not confirm that it can be left exposed. Obtain manufacturer approval before using it without a topcoat.\u003c\/span\u003e\u003c\/p\u003e","brand":"CEM Coatings Systems","offers":[{"title":"Default Title","offer_id":67713266778340,"sku":null,"price":241.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0845\/4537\/2388\/files\/cem-epix-fc-360-epoxy-basecoat-part-a-part-b.jpg?v=1792592763","url":"https:\/\/shop.decorativeconcretestore.com\/products\/cem-epix-fc-360-epoxy-floor-basecoat","provider":"The Decorative Concrete Store","version":"1.0","type":"link"}